GenetixBayEST. 2009
Jardin Measure · the meter, the sensor nodes and the probes · early access

Every reading, kept.

One handheld meter, a family of sensor nodes for the tent, probes that live in the pot and a camera that takes the same picture every day. They all twist together the same way, they all talk to each other, and every number they take is saved with its unit, its time, its place and how long ago it was calibrated. The pH probe has a cap you can't lose and a meter that tells you to put it back on.

10 headsone quarter-turn fitting on every one Designed
60,000readings kept on each Puck before it needs the hub Designed
13.7 monthsClimate Node on two AA cells, a reading every 60 s Modelled
3 mincap left off before the meter buzzes at you Designed
11 placesnamed in the tent, stamped on every reading Designed
The Jardin Measure family in a row: Measure One, the nodes, Canopy Sense, VisionCam, RootSense Pro and WeighSense Mini3D render · the Measure family

Concept renders made from the design files, not product photos. Every number on this page is a design target Designed or worked from one Modelled. Jardin has been prototyped for years; the production parts are built once tooling starts.

Dock, brain, head · three levels, one twist

Three parts. Every device is a combination.

Nothing in the range is a sealed box. A head twists onto a brain and a brain twists onto a dock, each with a green quarter-turn collar that clicks. When a sensor wears out you replace the head, or only its tip, and keep everything else.

A Climate Node pulled apart into its head, brain and dock3D render · Climate Node, apart
  1. Head

    The sensor and its calibration

    Each head has its own small processor that knows what it is, what it measures and when it was last calibrated. Move a head to another brain and its calibration goes with it.

  2. Brain

    Reads, stamps, stores, sends

    The Measure Puck is a 52 mm disc for the tent; Measure One is the same brain with a display, for your hand. Either one reads any head, stamps the time and place on the reading and keeps it.

  3. Dock

    Power and wiring

    A 60 × 60 mm plate that stays where you mounted it. The Bus Dock takes one cable for power and data. The Battery Dock takes two AA lithium cells and no cable at all.

The same Climate Node on a Bus Dock, left, and on a Battery Dock, right3D render · Bus Dock and Battery Dock
Twist one together · every pairing, in 360°

Pick a base. Pick a head. Turn it round.

Three bases and ten heads make thirty pairings, and every one is drawn. Drag the picture to turn the device right round. Two pairings are refused, and the page shows them apart and tells you why.

1 · the base
2 · the head

Power figures are arithmetic from design-target currents Modelled, not measurements. The pictures are 24-frame turntables rendered from the design files.

KeepWet · built for forgetting

The cap you can't lose. The meter that nags.

A pH electrode dies when its glass dries out, and it dries out because somebody put the cap down and walked off. So the cap is tied to the probe, a magnet tells the meter whether it's on, and the meter checks every few hours that there is still storage solution inside.

Measure One with the Liquid Duo head, its KeepWet cap hanging on the green tether
Cap off: it hangs on its tether
Measure One with the KeepWet cap twisted on
Cap on: quarter turn, one click
Try it · you took a reading, then what?
Measure One
Your phone

    A demo of the designed behaviour, not firmware. The timings are settings; these are the defaults.

    The Liquid Duo head lying down with its KeepWet cap off and the tether looped beside it3D render · Liquid Duo head and KeepWet cap
    The cap · JM-CAP-KW1
    • Tied to the head by a soft strap, so it can't be put down somewhere else.
    • A quarter turn and a click: the same motion as every other green part.
    • A well with a sponge ring that holds 3 mL of storage solution against the glass at any angle.
    • A wiper seal on the stem, so it doesn't weep in a drawer or a pocket.
    • A clear window with a fill line.
    • A magnet in the rim, and a switch in the head that feels it: the meter always knows whether the cap is on.

    Storage is pH electrode storage solution (3 M potassium chloride). Never plain or RO water.

    Eight reminders, in the order you'd need them

    Cap me

    Two buzzes, a beep, the screen says 'Cap me'.

    Your phone joins in

    Push notification from the Jardin app: 'Your pH probe is out of its cap'.

    Rinse, then cap

    The screen walks two ticks: Rinse, then Cap. The second tick fills itself when the cap clicks on.

    The cap has run dry

    Push notification and a red drop on the screen: 'Add ten drops of storage solution'; one tap reorders the bottle.

    Calibration due

    Amber dot beside pH and EC; readings are still taken and flagged cal_due.

    Calibration overdue

    Readings flagged cal_overdue; automatic dosing will not act on them.

    Electrode wearing out

    'This electrode is wearing out': reorder link, and how many weeks the last ones lasted.

    Left out overnight

    A guided revival: soak two hours in storage solution, then calibrate. The app says honestly when it did not work.

    The pH electrode is a standard 12 mm part that unscrews by hand, so a worn one is an electrode swap, not a new meter. Design life is 12 to 18 months with the cap kept wet Designed.

    The record · the reason for all of it

    A number is only useful if you can trust it later.

    Weeks after harvest, the question is what that plant lived through. So every device in the range saves the same kind of record, and saves all of it.

    One reading · illustrative
    value
    5.85The number, with its unit beside it. Always.
    unit
    pHCarried in the record itself, so nothing downstream has to guess.
    time
    2027-04-20 09:14:07From the device's own clock, set by the hub. A reading taken before the clock was set is marked, not thrown away.
    place
    ReservoirOne of 11 named places. A reading without a place is half a reading.
    device and head
    Measure One · Liquid Duo headWhich brain and which head took it, by serial number.
    calibrated
    12 days agoRead from the head. Past 30 days the reading is still taken, and marked as due.
    flags
    valid · freshWhat the device knew about its own reading: warming up, out of range, capped, sensor fault, estimated.

    Stored first, sent second

    Each device writes the reading to its own memory before it tries to send it. A Puck holds 60,000 of them and Measure One 500,000, so a dropped connection loses nothing.

    Kept on your own hub

    The record lives on the Jardin hub in your home. It works with the internet off.

    Shared only if you say so

    Sending a grow to the Bay, to a Bay Trial or to anyone else is a switch you turn on, per grow, and can turn off again.

    Honest about itself

    A reading the device has doubts about is kept and flagged, never quietly dropped or smoothed. Automatic dosing refuses to act on a reading whose calibration is overdue.

    The 11 places · set in the app, or by scanning the code on the dock
    Upper canopyCentre canopyLower canopyPlant edgeIntakeExhaustRoot zoneReservoirRunoffLung roomSpot check
    The range · what a grower buys

    A meter, the nodes, the probes and a camera.

    Each of these is an assembly of the same docks, brains and heads. Buy one, add another later, move a head from one to the next.

    Measure One with the Liquid Duo head

    The pH and EC meter that reminds you to cap it.

    Reads
    pH, EC, solution temperature
    Body
    152 × 44 × 24 mm
    Sealing
    IP67 mated, floats head-down
    A charge
    about 87 days at 20 min a day

    PAR Pocket: Measure One with the Light head

    PPFD and light bands in the hand; walks a grid and draws the canopy map.

    Reads
    PPFD, DLI, light bands
    Display
    turns over to read upright
    Keys
    three, for wet gloves
    Cell
    18650, replaceable, USB-C
    Taken apart

    Taken apart

    The body, the head, the electrode and the cap all come apart by hand. The cell is behind a coin-turn door.

    Electrode
    standard 12 mm, unscrews
    Cap
    tethered, quarter turn
    Back
    magnet, parks on a pole
    Stores
    500,000 readings

    Battery life and bus power are worked from design-target currents Modelled. Sizes and ratings are design targets Designed. Drag any picture marked 360° to turn it round.

    The ten heads · 10 sensors, one fitting

    Ten heads. Any of them on any brain.

    A head announces itself when it clicks on: what it is, what it measures, in what units, and when it was last calibrated. A new kind of head works with the brain you already own.

    The ten Measure heads in a row: Climate, CO2, Light, Canopy, Airflow, Pressure, Liquid Duo, Media, Port and Canopy Sense3D render · the ten heads

    Climate head

    Wear part: RH tip. 24 months in a tent.

    CO2 head

    Wear part: Splash membrane. 12 months.

    Light head

    Wear part: Diffuser dome. Replace when scratched or stained; the head is then recalibrated.

    Canopy head

    Wear part: RH tip. 24 months in a tent.

    Airflow head

    Wear part: Bridge guard. Replace if bent.

    Pressure head

    Wear part: Tube set, 2 x 2 m, with wall grommet. Replace if kinked.

    Liquid Duo head

    Wear part: pH electrode, double junction, gel, S7. 12 to 18 months with the cap kept wet.

    Media head

    Wear part: Tine set. Replace if bent.

    Port head

    Wear part: Port blanking cap. Replace if lost.

    Canopy Sense head

    Wear part: RH tip. 24 months in a tent.

    In a 4 x 4 · the J44 Measure kit Modelled

    Nine devices. Every place that matters.

    One set for a 4 x 4 tent: the canopy centre, both edges, under the leaves, the intake, the root zone, the filter and the reservoir. Hover a number to find it.

    reservoir lightintakeexhaust 123456789 Diagram · a tent from the side, not to scale
    1. 1

      Canopy Sense · Centre canopy

      Hung over the middle plant: temperature, humidity, CO2, leaf temperature and light in one body.

    2. 2

      Climate Node · Intake

      What the air is like coming in, before the plants change it.

    3. 3

      Climate Node, wireless · Lower canopy

      Under the leaves, where humidity collects and mould starts.

    4. 4

      Light Node, wireless · Plant edge

      One at each edge of the canopy, so you see how much light the corners lose.

    5. 5

      Light Node, wireless · Plant edge

      The second of the pair.

    6. 6

      Root Node · Root zone

      Two RootSense Pro probes in two pots, with two sockets free.

    7. 7

      Pressure Node · Exhaust

      Across the carbon filter: shows the tent is under negative pressure and when the filter is loading up.

    8. 8

      VisionCam · Upper canopy

      The same picture every day.

    9. 9

      Measure One · Reservoir, by hand

      pH and EC at the reservoir, then parked on a pole by its magnet.

    The five devices on the tent's bus draw 2.19 W together, worked from design-target currents Modelled; three more run on cells and Measure One on its own. A drawing of where things go; a render of the kit inside a tent is still to come.

    Why it's built this way

    Decisions you can see.

    Six choices in the drawings, and the reason for each.

    Nothing lights up in the dark
    01

    Nothing lights up in the dark

    Every light ring switches off for the tent's dark period, and the camera has no flash and no lamp. A status light is not worth a light leak in flower.

    A head knows what it is
    02

    A head knows what it is

    The calibration lives in the head, not the brain. Swap a head between two brains and both readings stay true; add a new kind of head and the old brain reads it.

    Wear parts come off by hand
    03

    Wear parts come off by hand

    The pH electrode unscrews. The humidity sensor is a plug-in tip. The light dome, the splash membrane and the tines are each a part number. The thing that wears out is never the thing that costs the most.

    No mains anywhere
    04

    No mains anywhere

    Everything runs from the 24 V Jardin Core bus, from two AA cells or from its own rechargeable cell. Nothing in the range switches or carries mains.

    A sensor, not a safety device
    05

    A sensor, not a safety device

    The CO2 head is for control and for the record. If you enrich a tent, the Air Guard room monitor is the safety device, and it stays a separate thing with its own alarm.

    Canopy Sense, now on the same Puck
    06

    Canopy Sense, now on the same Puck

    The canopy sensor that WaterWorks already hangs over the plants becomes one more head: the same body, on the same brain and dock as everything else.

    Specs · design targets Designed

    The numbers, labelled for what they are.

    Each accuracy below is the target the design is built to reach, and the last column is how you would check it yourself at home. None has been measured on a built unit yet.

    MeasuresRangeAccuracy targetHow you check it
    Air temperature-10 to 60 °C±0.2 °C, 10 to 40 °CTwo Pucks side by side agree within 0.3 °C
    Relative humidity0 to 100 %RH±2 %RH, 20 to 80 %RH75 %RH salt pouch (sodium chloride), 12 h
    CO2400 to 5,000 ppm±(50 ppm + 5 % of reading), 400 to 2,000 ppm (the sensor maker states ±(50 ppm + 3 %))Outdoor air reads 420 ppm ± 50 ppm
    PPFD, 400 to 700 nm0 to 3,000 µmol/m²/s±5 % against a reference quantum sensor under the four reference spectra; cosine error under 5 % at 60 degreesTwo Light heads under the same light agree within 4 %
    Leaf temperature (infrared)0 to 60 °C±0.5 °C at 15 to 30 cm, emissivity 0.97Aimed at a matt black card at room temperature it matches air temperature within 0.5 °C
    Air speed0 to 7 m/s±0.4 m/s (5 % of full scale): for comparing places and finding dead air, not for absolute slow speedsCapped head reads under 0.4 m/s
    Differential pressure-125 to 125 Pa±(0.1 Pa + 3 % of reading)Ports joined read 0.0 Pa ± 0.1
    pH0 to 14 pH±0.02 pH after a two-point calibration, 15 to 30 °CPH 7.00 pouch reads 7.00 ± 0.05; slope 90 to 105 %
    Electrical conductivity at 25 °C0 to 10 mS/cm±2 % of reading, 0.2 to 5 mS/cm1.413 mS/cm pouch reads within 2 %
    Volumetric water content0 to 100 % by volume±3 % by volume with the profile for the medium; ±1.5 % by volume after the grower's own two-point calibrationProbe in air reads 0; in water reads the probe's water figure ± 2 %
    Bulk EC of the medium0 to 10 mS/cm±(5 % of reading + 0.02 mS/cm)1.413 mS/cm pouch
    Weight0 to 80,000 g±0.05 % of full scale; drift under 0.02 % of full scale per 10 °CA 1,000 g reference reads 1,000 g ± 5 g

    What's done

    • Designed and specified. Every dock, brain, head and probe drawn to size, with each electronic and mechanical part chosen and costed, and every assembled render checked against its parts list.
    • One language for all of it. A single map of what each device reports and how, so the handheld, the nodes, the probes and the hub read each other.
    • Rules that are tested. Which head may go on which base, how much each draws and how long the cells last are checked automatically every time the design changes.

    What's not done yet

    • Circuit boards and enclosures. The circuit drawings, board layouts and mould-ready enclosure drawings come next.
    • Software for the devices. The behaviour on this page is designed, not yet running on hardware.
    • Any measurement. The first build is five development kits, to test every accuracy and battery figure here against reference instruments.
    Founding Members · first in line

    Help take Measure from drawings to your tent.

    Reserve on Fund the Bay with a refundable deposit, or join the waitlist to hear when the first development kits are built and tested.