Size your grow room properly.

Fans, intake, filters, cooling, dehumidifiers, CO₂, lights, circuits and nutrient mixes. Plain answers first, every formula one tap away, and a source for every number. No brands, nothing to buy, and nothing you type leaves your browser.

Professor Greenleaf at a laptop
Whole tent plannerEnter the tent and lights once. Get the fan, intake, filter, AC, dehumidifier, CO₂ and circuits in one printable, shareable plan.

One job at a time

The house view, up front. Passive intake suits most growers. Oversize your lights and dim them. Watt for watt, every device heats the same. And size for the worst case: everything at 100%.

Every constant and rule of thumb

One shared module, calc-core.js, holds every number below, and every calculator and Calculate it properly guide uses the same ones. Machine-readable: calculators.json.

Show all 73 constants
ConstantValueWhat it isEvidence
BTU_PER_W3.412 BTU/h per WEvery watt drawn from the wall becomes 3.412 BTU/h of heat in the room, whatever the deviceEstablished
BTU_PER_TON12000 BTU/h per tonOne ton of coolingEstablished
FT3_PER_M335.3147 ft³ per m³Volume conversionEstablished
M3H_PER_CFM1.699 m³/h per CFMAirflow conversionEstablished
L_PER_GAL3.78541 L per US galWater conversionEstablished
PINT_PER_L2.11338 US pints per LDehumidifier ratings are in US pints/dayEstablished
KG_PER_LB0.453592 kg per lbMass conversionEstablished
SENSIBLE_AIR1.08 BTU/h per CFM per °FHeat one CFM of standard air carries per °F of temperature rise (60 min × 0.075 lb/ft³ × 0.24 BTU/lb·°F)Established
EXCHANGE_MIN1 minutesDefault: replace the whole tent's air once a minute (the KB range is every 1–3 minutes)Grower practice
FILTER_STD1.25 ×Carbon filter airflow loss, typicalGrower practice
FILTER_HEAVY1.5 ×Carbon filter loss, thick bed, pre-filter or an older loaded filterGrower practice
DUCT_PER_M0.03 + per metreDuct run loss: about +3% per metre (+10% per 10 ft) of smooth ductGrower practice (rule of thumb; real loss depends on duct type and speed)
BEND_900.15 + per bendEach 90° bend: about +15% (more for tight or crushed flex duct)Grower practice (rule of thumb)
HEADROOM0.25 +Speed-controller headroom so the fan runs near 75–80% instead of flat outGrower practice
MIN_DT_F2 °FBelow about 2 °F (1 °C) between intake air and your maximum, exhaust alone cannot cool the spaceEstablished (follows from q = 1.08 × CFM × ΔT)
FAN_W_PER_CFM0.12 W per rated CFMRough power draw of an EC mixed-flow inline fan at full speed (for the planner's electrical total)Estimate
INTAKE_RATIO2.5 × exhaust duct areaPassive intake opening area (KB rule of thumb 2–3×; we default to the middle)Grower practice
MESH_FREE0.6 open fractionBug mesh or a pre-filter sock leaves roughly 60% of the hole openEstimate
INTAKE_FAN0.75 × exhaust airflowIf you do fit an intake fan, keep it at about 70–80% of the exhaust so the space stays under negative pressureGrower practice
ACTIVE_CFM800 CFMAbove about 800 CFM (an 8-inch fan running hard) passive ports get large: consider an active intakeGrower practice
INTAKE_RUN_M3 mIntake ducted from further than about 3 m (10 ft) away needs a fan to pull through itGrower practice
FILTER_MATCH_LO1 × fan CFMFilter rated airflow should be at least the airflow you actually runGrower practice
FILTER_MATCH_HI1.5 × fan CFMUp to ~1.5× is better: slower air through the bed means longer contact and longer carbon lifeGrower practice
PERSON_BTU450 BTU/h per personHeat from a person doing light work (ASHRAE: about 250 sensible + 200 latent)Established
U_GOOD0.06 BTU/h·ft²·°FWell-insulated room (about R-16 overall)Established (typical assembly)
U_AVG0.1 BTU/h·ft²·°FAverage insulated stud walls (about R-10 overall)Established (typical assembly)
U_POOR0.25 BTU/h·ft²·°FUninsulated framed walls (about R-4)Established (typical assembly)
U_SHED0.6 BTU/h·ft²·°FBare garage, shed or metal buildingEstimate
AC_MARGIN0.2 +Cooling margin over the calculated load (homes keep within ~15%; grow rooms run near flat out, so 20% is common)Grower practice
AC_EER10 BTU/h per WRough efficiency of a room or portable AC, for the electrical estimate (mini-splits do better)Estimate
TRANSPIRED0.97 fractionShare of the water a plant takes up that it transpires into the airEstablished
NIGHT_RATE0.1 × day rateNight transpiration per hour as a share of the lights-on rateSupported (other crops)
DEHU_MARGIN1.25 ×Dehumidifier margin over the average daily water (the AC also pulls water while it runs)Grower practice
AHAM_TO_DOE0.7 ×Old AHAM pints/day (80 °F, 60% RH) to the 2019 DOE rating (65 °F, 60% RH): about 70 → 50Established
DEHU_IEF_S1.3 L per kWhFederal minimum efficiency, portable units up to 25 pints/day (2019 rating); used to estimate the heat when you don't know the wattsEstablished (regulation)
DEHU_IEF_M1.6 L per kWhFederal minimum, portable units 25–50 pints/dayEstablished (regulation)
DEHU_IEF_L2.8 L per kWhFederal minimum, portable units over 50 pints/dayEstablished (regulation)
WATER_SEEDLING0.25 L per plant per dayStage helper: seedlingGrower practice (varies with pot, light and VPD)
WATER_VEG1 L per plant per dayStage helper: vegGrower practice
WATER_FLOWER2 L per plant per dayStage helper: flower (4 plants in a 4 × 4 ft tent ≈ 5.4 L/m²/day, inside the guides' 3–6 L/m²/day)Grower practice
CO2_AMBIENT420 ppmOutdoor CO₂Established
CO2_M44.01 g/molMolar mass of CO₂ (density from the ideal gas law at room temperature, ≈ 1.83 kg/m³ at 20 °C)Established
ACH_TIGHT0.1 air changes per hourSealed room, well tapedEstimate
ACH_SEALED0.25 air changes per hourSealed room, averageEstimate
ACH_LEAKY2 air changes per hourZipped tent or leaky room, exhaust offEstimate
CO2_UPTAKE4 g CO₂ per m² canopy per hourNet canopy uptake at high light and ~1,000 ppm (≈ 25 µmol/m²/s)Estimate from leaf data
PROPANE_CO23 lb CO₂ per lb fuelPropane burner: C₃H₈ + 5 O₂ → 3 CO₂ + 4 H₂O (132 ÷ 44.1)Established (stoichiometry)
PROPANE_H2O1.63 lb water per lb fuelPropane burner: water vapour madeEstablished (stoichiometry)
PROPANE_BTU21600 BTU per lb fuelPropane burner: heat released (higher heating value)Established
NG_CO22.74 lb CO₂ per lb fuelNatural gas burner (as methane): CH₄ + 2 O₂ → CO₂ + 2 H₂O (44 ÷ 16)Established (stoichiometry)
NG_H2O2.25 lb water per lb fuelNatural gas burner: water vapour madeEstablished (stoichiometry)
NG_BTU23900 BTU per lb fuelNatural gas burner: heat released (higher heating value)Established
CO2_PEL5000 ppm8-hour workplace limit (OSHA PEL, NIOSH REL, ACGIH TLV)Established
CO2_STEL30000 ppm15-minute short-term limit (ACGIH STEL, NIOSH ST)Established
CO2_IDLH40000 ppmImmediately dangerous to life or healthEstablished
DLI_K0.0036 mol·s per µmol·hDLI = PPFD × hours × 0.0036Established
CANOPY_CAPTURE0.85 fractionShare of the fixture's photons that land on the canopy in a reflective tent (assumption)Estimate
EFF_OLD1.5 µmol/JOld or low-end LED at the wall (older-generation and blurple panels, low-bin no-name diodes driven hard): often worse than double-ended HPS; independent 2014 tests measured LED fixtures at 0.89–1.70Supported (independent tests; founder's field experience 1.3–1.7)
EFF_HPS1.7 µmol/JDouble-ended HPS at the fixture (independent tests 1.66–1.72)Established
EFF_BUDGET2.3 µmol/JBudget LED panel at the wall (low-bin chips driven hard, budget driver)Supported (arithmetic from datasheets)
EFF_MID2.6 µmol/JMid-tier LED at the wallSupported
EFF_TOP3 µmol/JTop-tier LED at the wall (about 6% of listed fixtures in 2022)Established
GB_W_PER_FT250 W/ft² of dimmable capacityGenetixBay recommendation: oversize and dim down. Too much is better than not enoughHouse position (founder)
GAL_IMP4.54609 L per imperial gallonImperial (UK) gallon; most North American labels mean the US gallon (3.785 L)Established
P_FROM_P2O50.436 ×Elemental P from a label's P₂O₅ (2 × 30.974 ÷ 141.94)Established
K_FROM_K2O0.83 ×Elemental K from a label's K₂O (2 × 39.098 ÷ 94.20)Established
PPM500500 ppm per EC 1.0Hanna/NaCl '500' scale (TDS meters)Established
PPM700700 ppm per EC 1.0'700' (KCl) scaleEstablished
WATER_USE_M24 L per m² canopy per dayPlanning water use in flower (range 3–6 L/m²/day; 1 mm a day = 1 L/m²)Grower practice
RES_DAYS_LO3 daysReservoir holds at least 3 days of water use, so EC and pH swing lessGrower practice
RES_DAYS_HI5 days…and up to 5 daysGrower practice
CONTINUOUS0.8 × breaker ratingContinuous loads (3 h or more, which every grow light is) may use only 80% of the breakerEstablished (code)
PF0.95 power factorDrivers and ballasts draw slightly more amps than watts ÷ volts; we divide by 0.95 to be safeEstimate

Sources

Show all 32 sources
  1. ASHRAE. 2021. ASHRAE Handbook: Fundamentals. Ch. 1 (psychrometrics: sensible heat of air, q = 1.08 × cfm × ΔT at standard air), Ch. 18 (heat gain from people, lighting and equipment), Ch. 21 (duct design: fitting and friction losses), Ch. 26–27 (thermal resistance of building assemblies). ASHRAE, Atlanta. https://www.ashrae.org/technical-resources/ashrae-handbook
  2. ASHRAE. 2019. ASHRAE Handbook: HVAC Applications, chapter 'Control of gaseous indoor air contaminants' (sorbent bed depth and residence time govern removal). https://www.ashrae.org/technical-resources/ashrae-handbook
  3. NIST. Guide for the Use of the International System of Units (SP 811), Appendix B: conversion factors (1 W = 3.412 142 BTU/h; 1 ft³ = 0.028 316 8 m³; 1 US gal = 3.785 412 L). https://www.nist.gov/pml/special-publication-811
  4. AMCA/ASHRAE Standard 210-16: Laboratory methods of testing fans for certified aerodynamic performance rating (why 'free air' CFM falls as static pressure rises). https://www.amca.org/
  5. GenetixBay Knowledge Base. Airflow: air exchange, canopy air speed and fan placement (one tent volume every 1–3 min; +25–50% for a carbon filter and ducting; passive intake ≈ 2–3× exhaust duct area). https://genetixbay.com/knowledge/environment/airflow.html
  6. GenetixBay Knowledge Base. LED vs HPS: the heat and power-bill hype, and an LED buyer-beware guide (fixture µmol/J tiers, 85% canopy capture, watt-for-watt house advice, 1 W = 3.412 BTU/h). https://genetixbay.com/knowledge/equipment/led-vs-hps-hype-and-buyer-beware.html
  7. GenetixBay Knowledge Base. PPFD and DLI by stage, with the evidence (stage targets; DLI = PPFD × hours × 0.0036). https://genetixbay.com/knowledge/environment/ppfd-dli-by-stage.html
  8. GenetixBay Knowledge Base. CO₂ enrichment (targets 800–1,200 ppm at lights-on only; worth it only sealed and at high light). https://genetixbay.com/knowledge/environment/co2-enrichment.html
  9. Rodriguez-Morrison V, Llewellyn D, Zheng Y. 2021. Cannabis yield, potency, and leaf photosynthesis respond differently to increasing light levels in an indoor environment. Frontiers in Plant Science 12:646020. https://doi.org/10.3389/fpls.2021.646020
  10. Kusuma P, Pattison PM, Bugbee B. 2020. From physics to fixtures to food: current and potential LED efficacy. Horticulture Research 7:56. https://doi.org/10.1038/s41438-020-0283-7
  11. Nelson JA, Bugbee B. 2014. Economic analysis of greenhouse lighting: light emitting diodes vs. high intensity discharge fixtures. PLoS ONE 9(6):e99010 (independent fixture efficacy tests). https://doi.org/10.1371/journal.pone.0099010
  12. Chandra S, Lata H, Khan IA, ElSohly MA. 2008. Photosynthetic response of Cannabis sativa L. to variations in photosynthetic photon flux densities, temperature and CO₂ conditions. Physiology and Molecular Biology of Plants 14(4):299–306. https://doi.org/10.1007/s12298-008-0027-x
  13. ACCA. Manual S: Residential Equipment Selection (cooling equipment kept close to the calculated load; oversizing short-cycles and dehumidifies poorly). https://www.acca.org/standards/technical-manuals/manual-s
  14. US DOE. 10 CFR 430 Subpart B, Appendix CC: Uniform test method for portable air conditioners (seasonally adjusted cooling capacity, which counts the infiltration a single-hose unit causes). https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-B/appendix-Appendix%20CC%20to%20Subpart%20B%20of%20Part%20430
  15. US DOE. 10 CFR 430 Subpart B, Appendix X1 (dehumidifier test at 65 °F and 60% RH, required from June 2019; the older AHAM DH-1 rating used 80 °F and 60% RH) and 10 CFR 430.32(v) (minimum integrated energy factor, L/kWh). https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-B/appendix-Appendix%20X1%20to%20Subpart%20B%20of%20Part%20430
  16. ENERGY STAR. Dehumidifiers: key product criteria and the 2019 capacity re-rating (a unit once sold as 70 pints/day is about 50 pints/day on the new test). https://www.energystar.gov/products/dehumidifiers
  17. Taiz L, Zeiger E, Møller IM, Murphy A. 2015. Plant Physiology and Development, 6th ed., Ch. 4 (about 97% of the water a plant absorbs is lost by transpiration). Sinauer. https://global.oup.com/academic/product/plant-physiology-and-development-9781605353531
  18. Caird MA, Richards JH, Donovan LA. 2007. Nighttime stomatal conductance and transpiration in C3 and C4 plants. Plant Physiology 143(1):4–10 (night transpiration commonly 5–15% of daytime, up to ~30%). https://doi.org/10.1104/pp.106.092940
  19. Alduchov OA, Eskridge RE. 1996. Improved Magnus form approximation of saturation vapor pressure. Journal of Applied Meteorology 35(4):601–609. https://doi.org/10.1175/1520-0450(1996)035%3C0601:IMFAOS%3E2.0.CO;2
  20. NOAA Global Monitoring Laboratory. Trends in atmospheric carbon dioxide (global mean above 420 ppm since 2023). https://gml.noaa.gov/ccgg/trends/
  21. OSHA. Carbon dioxide, chemical data: PEL 5,000 ppm 8-hour TWA (29 CFR 1910.1000, Table Z-1). https://www.osha.gov/chemicaldata/183
  22. NIOSH Pocket Guide to Chemical Hazards: carbon dioxide (REL 5,000 ppm TWA; short-term 30,000 ppm; IDLH 40,000 ppm). ACGIH lists the same TLV-TWA 5,000 ppm and TLV-STEL 30,000 ppm. https://www.cdc.gov/niosh/npg/npgd0103.html
  23. NFPA 70, National Electrical Code (2023): Art. 100 (continuous load = 3 hours or more), 210.19(A)(1) and 210.20(A) (conductors and breakers at 125% of continuous load, i.e. load ≤ 80%), 210.8 (GFCI locations), 400.12 (flexible cords not a substitute for fixed wiring). https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70
  24. CSA C22.1, Canadian Electrical Code, Part I: Rule 8-104 (continuous loads limited to 80% of the breaker rating) and Rule 26-700 series (receptacles and GFCI). https://www.csagroup.org/store/product/CSA%20C22.1:24/
  25. OSHA. 29 CFR 1910.303(b)(2): listed equipment must be used per its listing and labelling (power strips are not to be chained together). https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.303
  26. Combustion stoichiometry and heating values of propane and methane: NIST Chemistry WebBook (enthalpies of combustion) and US EIA, 'Units and calculators: British thermal units' (propane ≈ 91,500 BTU per gallon at 4.24 lb per gallon). https://webbook.nist.gov/chemistry/
  27. Mattson NS, Lieth JH. 2019. Liquid culture hydroponic system operation. In: Raviv M, Lieth JH, Bar-Tal A (eds), Soilless Culture: Theory and Practice, 2nd ed. Elsevier, pp. 567–585 (EC monitoring, replenishment and replacement). https://doi.org/10.1016/B978-0-444-63696-6.00012-8
  28. NIST. Atomic weights and isotopic compositions (P 30.974, K 39.098, O 15.999), for the P₂O₅ and K₂O conversion factors. https://www.nist.gov/pml/atomic-weights-and-isotopic-compositions-relative-atomic-masses
  29. Allen RG, Pereira LS, Raes D, Smith M. 1998. Crop evapotranspiration (FAO Irrigation and Drainage Paper 56), Ch. 1 (1 mm of water over 1 m² = 1 litre). https://www.fao.org/4/x0490e/x0490e04.htm
  30. GenetixBay Knowledge Base. EC vs PPM: the 500 and 700 scales. https://genetixbay.com/knowledge/ph-ec/ec-ppm-scales.html
  31. GenetixBay house position (founder's field experience, decades of indoor rooms): passive intake for most growers; oversize lights and dim down; replace HPS watt for watt unless the LED is top tier. https://genetixbay.com/editorial-policy
  32. GenetixBay survey of published free-air ratings for mixed-flow inline fans sold for grow rooms, 2026 (ranges only; no brands).

← All topics · Symptom checker

Professor Greenleaf

Grow with the Professor.

The GenetixBay community is coming: honest grow journals, permanent GB-IDs for genetics, and a Professor who answers with citations. Founding Members get first access and a permanent badge.