# VPD explained: vapour pressure deficit for cannabis growers

> VPD is how hard the air pulls water out of the leaf, in kPa. Common targets are about 0.4–0.8 kPa for seedlings and clones, 0.8–1.2 kPa in veg and 1.0–1.5 kPa in flower, calculated from leaf temperature rather than air temperature. Most of these bands come from grower and greenhouse practice; cannabis-specific VPD trials are still scarce.

- Canonical: https://genetixbay.com/knowledge/environment/vpd-explained.html
- Category: Environment · Level: Intermediate
- Evidence: Supported · Status: Draft: awaiting expert review (some figures are being checked)
- Stage: Seedling, Veg, Flower, Ripening · Systems: Any system
- Updated: 2026-10-31 · Licence: CC BY-SA 4.0 (https://creativecommons.org/licenses/by-sa/4.0/), attribute "GenetixBay Knowledge Base (genetixbay.com/knowledge)"

## Questions and answers

**What is VPD and why does it matter for cannabis?** VPD, vapour pressure deficit, is the gap in kPa between the saturated water vapour inside a cannabis leaf and the vapour actually in the room air. It sets the pull on transpiration, which moves water and calcium to new growth. Too low, below about 0.4 kPa, invites bud rot and mildew; too high, above about 1.6–1.8 kPa, closes stomata and cuts [photosynthesis](https://genetixbay.com/knowledge/glossary/photosynthesis.md).

**What VPD should I run in veg and flower?** Common cannabis VPD targets, calculated from leaf temperature, are about 0.8–1.0 kPa in early veg, 0.9–1.2 kPa in late veg, 1.0–1.4 kPa in flower weeks 1–5 and 1.2–1.5 kPa from week 6 to harvest. These bands are grower practice backed by general plant physiology; no published trial has pinned an optimum VPD per stage for cannabis.

**How do I calculate VPD with leaf temperature?** To calculate leaf VPD, find saturation vapour pressure with es(T) = 0.6108 × exp(17.27 × T / (T + 237.3)) in kPa. Leaf VPD equals es at leaf temperature minus es at air temperature × RH/100. Measure leaf temperature with an infrared thermometer at emissivity about 0.95, aimed at a fully lit top leaf, or use a canopy IR sensor.

**What humidity do I need at 26 °C to hit 1.2 kPa?** At 26 °C (79 °F) air, you need about 53 % relative humidity to hit 1.2 kPa leaf VPD in a typical LED room where leaves sit about 2 °C below air temperature. Under HID, where leaves are near air temperature, the same target needs roughly 64 % RH. Measure your actual leaf offset with an infrared thermometer before setting the [humidifier](https://genetixbay.com/knowledge/glossary/humidifier.md).

**Is leaf VPD or air VPD the right number?** Leaf VPD is the right number, because it is what the cannabis plant actually feels; air VPD assumes the leaf is at air temperature. Under LEDs, healthy leaves often run 1–3 °C cooler than air, so at 26 °C and 60 % RH an app shows 1.34 kPa air VPD while the leaf is only at 0.97 kPa, and growers end up running the room too humid.

**My VPD is perfect but plants still look stressed, why?** Cannabis plants can look stressed at a perfect VPD because the cause lies elsewhere. Check the RH sensor with a two-point salt test, since cheap sensors drift 3–5 %; confirm it sits at canopy height in moving air; compare leaf temperatures top to bottom for airflow gaps; and rule out a dry pot, wrong reservoir temperature or [root disease](https://genetixbay.com/knowledge/glossary/root-rot.md). VPD cannot fix a sick [root zone](https://genetixbay.com/knowledge/glossary/root-zone.md).

**Short answer.** Vapour pressure deficit (VPD) is the gap between how much water vapour the air inside a leaf holds (saturated, at leaf temperature) and how much the room air actually holds, in kilopascals (kPa). It sets the "pull" on transpiration. Common working targets are **0.4–0.8 kPa for [seedlings](https://genetixbay.com/knowledge/glossary/seedling.md) and clones, 0.8–1.2 kPa in veg, 1.0–1.5 kPa in flower**, calculated with **leaf** temperature. Treat those bands as *Grower practice* backed by general plant physiology, not as cannabis-proven optima.

## What's happening

The [air spaces](https://genetixbay.com/knowledge/glossary/air-filled-porosity.md) inside a leaf are effectively at 100 % RH at the leaf's own temperature. Water moves from high vapour pressure (leaf) to low (room). The bigger the difference, the faster the plant transpires, and the faster water, calcium and other mass-flow nutrients move from root to shoot.

- **Too low** (below ~0.4 kPa outside propagation): transpiration stalls, calcium delivery to new growth and buds slows, leaf surfaces stay wet, and fungal pathogens such as *Botrytis* and [powdery mildew](https://genetixbay.com/knowledge/glossary/powdery-mildew.md) get their favourite conditions [5]. A 2025 study held cannabis at roughly 78–98 % RH and found delayed flowering, lower biomass and lower [cannabinoid](https://genetixbay.com/knowledge/glossary/cannabinoid.md) content compared with roughly 37–58 % RH [3].
- **Too high** (above ~1.6–1.8 kPa): stomata partially close to save water, CO₂ intake drops, and photosynthesis falls even though the light is on. Leaves taco, edges crisp, and the root zone has to work harder to keep up.

RH alone is a poor control target because the same 60 % RH means a very different pull at 20 °C than at 30 °C. VPD folds temperature and humidity into one number.

## The calculation

Saturation vapour pressure (kPa) at temperature T (°C), using the FAO-56 form of the Tetens equation [1]:

`es(T) = 0.6108 × exp(17.27 × T / (T + 237.3))`

- **Air VPD** = es(T_air) × (1 − RH/100)
- **Leaf VPD** = es(T_leaf) − es(T_air) × RH/100

Leaf VPD is what the plant feels. Measure leaf temperature with an infrared thermometer on a top, fully lit leaf (set emissivity around 0.95), or read it from a canopy IR sensor.

### How far is the leaf from the air?

Well-watered leaves usually sit **within about 2 °C (3.6 °F) of air temperature** under any light source; under water stress and still air the model in [2] puts leaves 8 °C (14 °F) above air under LED and 12 °C (22 °F) above under HPS. In practice:

| Situation | Typical leaf offset vs air | Notes |
|---|---|---|
| LED, healthy transpiring canopy, decent airflow | −1 to −3 °C (−2 to −5 °F) | The usual assumption is −2 °C. Measure your own. |
| HPS / double-ended HID | 0 to +2 °C (0 to +4 °F) | Radiant load warms the leaf. |
| Water-stressed or still air, any light | +2 to +8 °C or more | Stomata closed; the leaf can't cool itself [2]. |

## Numbers that matter

### Leaf VPD (kPa) with a −2 °C leaf offset (typical LED room)

| Air °C (°F) | 40 % | 50 % | 55 % | 60 % | 65 % | 70 % | 75 % | 80 % RH |
|---|---|---|---|---|---|---|---|---|
| 20 (68) | 1.13 | 0.89 | 0.78 | 0.66 | 0.54 | 0.43 | 0.31 | 0.19 |
| 22 (72) | 1.28 | 1.02 | 0.88 | 0.75 | 0.62 | 0.49 | 0.36 | 0.22 |
| 24 (75) | 1.45 | 1.15 | 1.00 | 0.85 | 0.70 | 0.56 | 0.41 | 0.26 |
| 26 (79) | 1.64 | 1.30 | 1.14 | 0.97 | 0.80 | 0.63 | 0.46 | 0.29 |
| 28 (82) | 1.85 | 1.47 | 1.28 | 1.09 | 0.90 | 0.72 | 0.53 | 0.34 |
| 30 (86) | 2.08 | 1.66 | 1.45 | 1.23 | 1.02 | 0.81 | 0.60 | 0.39 |

### Leaf VPD (kPa) with no offset (leaf = air; typical HID room)

| Air °C (°F) | 40 % | 50 % | 55 % | 60 % | 65 % | 70 % | 75 % | 80 % RH |
|---|---|---|---|---|---|---|---|---|
| 20 (68) | 1.40 | 1.17 | 1.05 | 0.94 | 0.82 | 0.70 | 0.58 | 0.47 |
| 22 (72) | 1.59 | 1.32 | 1.19 | 1.06 | 0.93 | 0.79 | 0.66 | 0.53 |
| 24 (75) | 1.79 | 1.49 | 1.34 | 1.19 | 1.04 | 0.90 | 0.75 | 0.60 |
| 26 (79) | 2.02 | 1.68 | 1.51 | 1.34 | 1.18 | 1.01 | 0.84 | 0.67 |
| 28 (82) | 2.27 | 1.89 | 1.70 | 1.51 | 1.32 | 1.13 | 0.94 | 0.76 |
| 30 (86) | 2.55 | 2.12 | 1.91 | 1.70 | 1.49 | 1.27 | 1.06 | 0.85 |

The difference between those two tables is the whole point: at 26 °C and 60 % RH, the "air VPD" app says 1.34 kPa, but an LED-lit leaf two degrees cooler is only at 0.97 kPa.

### RH needed for a target leaf VPD (−2 °C leaf offset)

| Air °C (°F) | 0.6 kPa | 0.8 kPa | 1.0 kPa | 1.2 kPa | 1.4 kPa |
|---|---|---|---|---|---|
| 20 (68) | 63 % | 54 % | 46 % | 37 % | 28 % |
| 22 (72) | 66 % | 58 % | 51 % | 43 % | 35 % |
| 24 (75) | 68 % | 62 % | 55 % | 48 % | 42 % |
| 26 (79) | 71 % | 65 % | 59 % | 53 % | 47 % |
| 28 (82) | 73 % | 68 % | 62 % | 57 % | 52 % |
| 30 (86) | 75 % | 70 % | 66 % | 61 % | 56 % |

### Working targets by stage

| Stage | Leaf VPD (kPa) | Typical air / RH that gets you there | Evidence |
|---|---|---|---|
| [Germination](https://genetixbay.com/knowledge/glossary/germination.md), seedlings, unrooted clones | 0.4–0.8 | 22–26 °C (72–79 °F), 65–80 % RH (domes) | Grower practice; propagation horticulture |
| Early veg | 0.8–1.0 | 24–27 °C (75–81 °F), 60–70 % RH | Grower practice |
| Late veg | 0.9–1.2 | 24–28 °C (75–82 °F), 55–65 % RH | Grower practice |
| Flower weeks 1–5 | 1.0–1.4 | 24–27 °C (75–81 °F), 50–60 % RH | Grower practice |
| Flower weeks 6+ / ripening | 1.2–1.5 | 20–25 °C (68–77 °F), 40–50 % RH | Grower practice; disease-risk logic [5] |
| Lights-off (any stage) | Keep above ~0.5 and stay well above [dew point](https://genetixbay.com/knowledge/glossary/dew-point.md) | Raise [dehumidification](https://genetixbay.com/knowledge/glossary/dehumidifier.md) before lights-off | Supported (condensation physics) |

## What to check first

1. **Is the sensor right?** Cheap RH sensors drift 3–5 % RH. Check against a fresh two-point salt test (75 % with sodium chloride, 33 % with magnesium chloride) before you chase numbers.
2. **Where is the sensor?** At canopy height, shaded from direct light, in moving air. A probe in the corner or on the floor reads a different room.
3. **What is the leaf actually doing?** Shoot leaf temperature at the top of the canopy, mid-canopy and lower. Big spreads mean an airflow problem, not a VPD-setpoint problem ([airflow](https://genetixbay.com/knowledge/environment/airflow.md)).
4. **Is the root zone keeping up?** A dry pot, cold or warm reservoir, or root disease looks exactly like "VPD too high". Rule it out before you add humidity.

## How to fix it

- **VPD too high (dry/hot):** lower air temperature first if you are above ~28 °C (82 °F); then add humidity (humidifier on a controller, or fewer air exchanges). Raise the light slightly or dim 10–15 % if leaves are above air temperature.
- **VPD too low (wet):** dehumidify, then gently raise temperature, then increase air exchange if outside air is drier. In late flower dehumidify on the **dark** period too; that is when RH spikes.
- **Big leaf-to-air gap:** improve canopy airflow; thin dense interior leaves ([defoliation](https://genetixbay.com/knowledge/training/defoliation-lollipopping.md)).

## How to confirm it worked

Leaves held flat and pointed slightly up, no tacoing, no droplets at lights-on; stable daily water use; new growth free of calcium-type spotting; no condensation on walls or buds at lights-off. Log leaf VPD for a week and check it stays inside your band for at least 80 % of lights-on hours.

## Common mistakes

- Using air VPD from an app while running LEDs, then running the room too humid. Low leaf VPD slows calcium delivery to new growth, which is the real story behind the *Myth* that "LEDs need more [Cal-Mag](https://genetixbay.com/knowledge/glossary/cal-mag.md)" ([Cal-Mag](https://genetixbay.com/knowledge/nutrients/cal-mag.md)).
- Chasing a single number all day. Plants tolerate excursions; sustained extremes are the problem.
- Dropping RH hard in early flower at the cost of temperature control. Stable is better than "perfect".
- Forgetting the night: lights-off RH spikes are where bud rot starts.
- Treating VPD as a cure-all. It won't fix a sick root zone.

## Evidence

The physics (Tetens/FAO-56 equation, leaf vs air vapour pressure) is *Established* [1]. Leaf temperature behaviour under different light sources is *Supported* by modelling [2]. Cannabis-specific evidence is thin: one recent study shows very high RH (low VPD) harms flowering, biomass and cannabinoids [3], and humidity is *Established* as a driver of cannabis bud rot and mildew [5]. Gas-exchange work on cannabis shows stomatal conductance and photosynthesis are temperature- and light-dependent [4], but there is no published trial that pins an optimum VPD per stage. The stage bands above are *Grower practice*.

## Sources

1. Allen RG, Pereira LS, Raes D, Smith M, 1998. Crop evapotranspiration: guidelines for computing crop water requirements (FAO Irrigation and Drainage Paper 56), Chapter 3. FAO. https://www.fao.org/4/x0490e/x0490e07.htm
2. Nelson JA, Bugbee B, 2015. Analysis of environmental effects on leaf temperature under sunlight, high pressure sodium and light emitting diodes. PLoS ONE 10(10): e0138930. https://pmc.ncbi.nlm.nih.gov/articles/PMC4598144/
3. Corredor-Perilla IC, Kwon H, Park J, 2025. High relative humidity in cannabis cultivation (effects on flowering, biomass and cannabinoids). Frontiers in Plant Science 16:1678142. https://doi.org/10.3389/fpls.2025.1678142
4. Chandra S, Lata H, Khan IA, ElSohly MA, 2008. Photosynthetic response of Cannabis sativa L. to variations in photosynthetic photon flux densities, temperature and CO2 conditions. Physiology and Molecular Biology of Plants 14(4):299–306. https://doi.org/10.1007/s12298-008-0027-x
5. Punja ZK, 2021. Emerging diseases of Cannabis sativa and sustainable management. Pest Management Science 77:3857–3870. https://pmc.ncbi.nlm.nih.gov/articles/PMC8451794/